Special design for scleral fixation
Balance haptic design provides perfect centralization and stability
360⁰ All Square Enhanced Edge
Real PCO Barrier
The innovative edge design tends to greatly reduce PCO risk by forming a geometric and mechanical barrier against cells proliferation. The edge design produces thinner lenses for equivalent power than competitors.
Exceptional Design
360⁰ All Square Enhanced Edge and premium material form a dual barrier against the risk of posterior capsule opacification after implantation. Recent studies have shown that square edge on posterior surface of the optic is the most important IOL-related factor against PCO
Ultra Definition
Advanced Vision of Aspheric Design
Ultra Definition optic design corrects spherical aberrations coming from both cornea and IOL. However, AcrivaUD IOLs have a slight negative asphericity, which maintains part of the positive aberration of the cornea, helping patient to keep better depth of focus.
Advantage of Ultra Definition Design
-
Improved contrast sensitivity under low light condition
-
Preserved depth of focus
-
Less sensitive to decentration
Premium Material
Best of Both Worlds!
Excellent material combination of 2-Oxiethylmethacrylate and 2-Hydroxymethacrylate monomers creates hydrophobic surface behavior with the advantage of hydrophilic flexibility.
Proven Hydrophobic Surface Behavior
AcrivaUD has similar contact angle measurements similar to pure hydrophobic IOLs. An independent comparative study showed that the hydrophobic surface of AcrivaUD is similar to that of pure hydrophobic competitors.
Benefits of Hydrophobic and Hydrophilic Monomers
-
No glistening
-
Limited PCO
-
High biocompatibility
-
Low inflammatory response
-
No calcification
-
Easy to fold and inject
-
MICS capability
-
Quickly unfolding in the eye
Better Flexibility
The elastic co-polymer of AcrivaUD has precise memory. Point Spread Function (PSF) shows that the optic quickly recovers its initial shape within one hour, much quicker than hydrophobic IOLs.
Wide Diopter Range
Complete Solution
AcrivaUD has a full range of diopters from -20.00D to +45.00D, in 0.50D increments. Special production is from -20.00D to 0.0D and from +32.00D to +45.00D in 0.50D increments.
Superior Chromatic Aberration Control
Abbe Number of AcrivaUD is 58, one of the highest numbers in the IOL market, measured by independent laboratory. Superior chromatic aberration control in all AcrivaUD lines.
The Importance of Abbe Number
Chromatic aberration is type of distortion in optical system formed by different wavelengths of light to have different focal points. The higher the Abbe number is the lower the chromatic dispersion is.
High MTF Values
Better Visual Quality
The MTF of all AcrivaUD lenses is checked one by one and value is always above international standards limits. AcrivaUD products demonstrates superior MTF and smooth surface topography, thanks to our innovative optic engineering.
Modular Transfer Function
MTF is a direct and quantitative measurement of optic system quality. The best result through obstacles is 0.7 at 100 lpm. According to international standards the MTF result at an IOL must be above 0.43 at 100 lpm3.
VSY Biotechnology has determined its own quality control limits far stricter than international standards.